World News

Industry news and insights from Europe and around the World

UK News

Latest news and developments in the United Kingdom

Products

Keep up-to-date with the latest new products and technology

Features

General articles, applications and industry analysis

R22 conversion is no fishy tale

FishUK: A spiral freezer plant at a Grimsby fish processing facility running on R22 is believed to be the first of its kind in the UK to be converted to operate on the new alternative R407F.

The conversion was carried out by Coldstar Refrigeration at Young’s Seafood Grimsby facility with the A-Gas R407F refrigerant Genetron Performax LT supplied by Climate Center.

With the use of R22 for servicing existing equipment finally being banned in Europe at the end of this year, plant running on R22 must either be replaced or retrofitted to run on an alternative.

R407F is a blend of three fluids, R32, R125 and R134a, and has an operating

Robert Franklin
Robert Franklin: “practical and cost-effective solution”

pressure similar to that of R22. The non-flammable gas is suitable for use in both medium and some low temperature commercial refrigeration applications.

Its makers claim it can reduce refrigeration energy use by up to 15%, cut CO2 emissions by up to 40%, and reduce overall operating costs by up to 10%. The gas also requires fewer plant modifications than other R22 alternatives.

The spiral freezer system at the Grimsby plant is based on a two-stage Grasso compressor with liquid injection, with a cooling capacity of around 80kW. The stand-alone system freezes fish fillets following processing, for storage or onward delivery.

Jay Burton of national contractor Coldstar Refrigeration said: “The conversion process required an oil change and some new gaskets and O-rings. Once the plant had been prepared, the gas change – using about 200kg of R407F – took just a day to complete, followed by inspection to ensure everything was running smoothly.”

Robert Franklin, Climate Center’s national sales manager for refrigeration, says: “The project is an excellent example of how R407F can extend the life of valuable plant and equipment currently dependent on R22. It offers a practical and cost-effective solution in wide range of applications. We expect take-up of the refrigerant to grow significantly over the coming months, as the final deadline for R22 approaches.”

Following the success of the project, the contractor has been commissioned by Young’s Seafood to convert the facility’s central refrigeration plant to run on R407F. This substantial project involves the main plant at the site, which provides cooling for all the storage rooms. It will require between 700 to 1000kg of R407F.

The collaborative project is being headed up by Jay Burton of Coldstar, Zach Wynne of Climate Center, and Roger Smith of A-Gas.

Latest News

15th April 2024

Invertek passes 3 million VFD landmark

UK: Welshpool-based Invertek Drives Ltd has celebrated producing its three millionth variable frequency drive.
15th April 2024

CDL opens Holmes Chapel branch

UK: Air conditioning distributor Cool Designs Ltd (CDL) has opened a new branch at Holmes Chapel near Crewe.
15th April 2024

Nidec to increase water cooling production

JAPAN: Nidec is to increase production of its coolant distribution unit (CDU) production line in Thailand from 200 to 2,000 units per month by June 2024.
15th April 2024

François Audo joins Enex as CEO

ITALY: François Audo has been appointed CEO of Enex Technologies, the Treviso-based manufacturer of cooling, heating, ventilation and refrigeration equipment.
15th April 2024

Cheap gas and policy changes hit heat pump sales

BELGIUM: Cheap gas and expensive bank loans are cited as two key reasons behind the dramatic fall in heat pump sales in Europe last year.
14th April 2024

IRAC 2024 returns to Dublin

IRELAND: IRAC 2024, Ireland’s biennial refrigeration and air conditioning exhibition, opens its doors next Friday with over 30 exhibitors showcasing their products and services.