World News

Industry news and insights from Europe and around the World

UK News

Latest news and developments in the United Kingdom

Products

Keep up-to-date with the latest new products and technology

Features

General articles, applications and industry analysis

A chiller for all seasons

UK: Carrier has delivered a high-efficiency R515B chiller upgrade at the Four Seasons Hotel in Park Lane, London, overcoming major access constraints and maintaining continuous cooling throughout the project. 

The contract involved the replacement of two ageing Carrier 30HX375 R134a chillers, originally installed in 2009, with two AquaForce 30XWV-ZE 1301A water-cooled chillers.

Delivered in partnership with East West Connect Ltd, the project required a specialist engineering approach due to the location of the plantroom within a restricted-access basement. With no viable route for full plant delivery, Carrier implemented a strip-down and rebuild strategy, dismantling the chillers off-site before transporting them in sections for reassembly on location.

At the same time, the hotel required uninterrupted cooling, placing additional pressure on programme delivery. The works were carried out in two phases, ensuring one chiller remained operational to avoid any disruption to guests or service.

Each chiller Carrier features variable speed compressors and R515B, an A1 non-flammable alternative to the standard R1234ze refrigerant option, with a GWP of around 293.

“In a live hospitality environment, safety and continuity are critical,” said Graham Smith, Carrier’s applied commercial director at Carrier. “By combining inverter-driven technology with a non-flammable refrigerant option and a flexible installation approach, we were able to deliver a solution that met the client’s operational and environmental priorities without compromise.”

During installation, a clash between one of the inverter drives and existing structural steelwork was identified through digital modelling. Carrier’s engineering team adapted the system design in real time, relocating the inverter within the plantroom to ensure a successful fit without compromising performance.

The full project was completed in six weeks, with both chillers installed and commissioned while maintaining uninterrupted cooling throughout the premises.

Latest News

21st September 2026

Dr Armin Frommer to join Vaillant as MD

GERMANY: Vaillant has appointed Dr Armin Frommer as managing director of the company from October 1 amongst changes to the company’s management.
21st September 2026

Scientists claim elastocaloric cooling breakthrough

HONG KONG: Scientists claim to have developed what is said to be the world’s first zero-degradation elastocaloric cooling device.
20th September 2026

Wolseley own-brand side stream filtration range

UK: Wolseley Pipe Centre has launched its own-brand JET Quad side-stream filtration range to improve water quality and help protect commercial cooling and heating systems.
20th September 2026

Europe needs access to efficient cooling

BELGIUM: EPEE has described the EU president’s state of the union address as a “rare moment” for electrification of heating and efficient cooling to be named in the same speech.
19th September 2026

Subcontractors stung by constant late payments

UK: Nearly 80% of subcontractors in the UK construction industry are paid late, and almost 75% are regularly in disputes with contractors.
19th September 2026

Engineer dies following Busan refrigerant leak

SOUTH KOREA: In an update to the report of a refrigerant leak on a Russian ship in Busan, the Russian Consulate has reported that one of the victims has since…