Haier’s integrated HVAC solution to Larnaca heat

CYPRUS: Haier has delivered an integrated HVAC solution to Larnaca’s new district local government offices.

The project demanded reliable year-round comfort, strong energy efficiency, low noise levels, and a modern aesthetic suited to a contemporary working environment. 

With the demands of the Mediterranean climate, the system also had to handle high summer cooling loads while keeping running costs under control. 

To meet these requirements, Haier delivered an integrated solution combining MRV5-H systems, Revive Plus split units, and a heat recovery ventilation (ERV) network for heating, cooling, and fresh air supply throughout the building.

High seasonal efficiency, the ability to support long piping distances, and ultra-quiet indoor operation were all essential. Fresh air supply also had to be incorporated across multiple office spaces without increasing energy losses, making ERV integration a key part of the design. 

To meet the spec, MRV cassette units and ERV systems had to be fitted within restricted ceiling voids while still allowing access for servicing and maintenance. On the roof, high capacity outdoor units needed to be lifted and positioned safely using a specialised crane. All of this had to be completed within a demanding four-month programme.

The outdoor installation included four MRV5-H modules with a total capacity of 64hp (181kW), supported by two Revive Plus split units providing an additional 10kW. Together, these systems deliver heating and cooling performance across the entire office complex.

Inside the building, 38 MRV full-size and mini cassette units were installed, along with two wall-mounted Revive Plus units. For ventilation, six ERV units were added to provide a total fresh air exchange rate of 5,350m3/h.

To give both occupants and facility managers full control, each indoor unit was paired with an individual HW-SA201ABK wired controller. In addition, two central HCSA164DBT controllers were installed to allow building-wide monitoring, energy optimisation, and coordination between the ventilation and MRV systems.

Latest News

11th September 2026

European F-gas prices remain stable

EUROPE: Refrigerant prices in Europe remained relatively stable in the second quarter of 2026, according to latest figures published by the European Commission.
11th September 2026

James Bailey joins Lowe Rental

UK: Commercial refrigeration rental company Lowe Rental has appointed James Bailey as technical director of refrigeration-as-a-service.
11th September 2026

Beijer Ref acquires majority stake in FG Europe

SWEDEN/GREECE: Wholesaler Beijer Ref has signed an agreement to acquire 75% of the shares in FG Europe, with an option to acquire the remaining shares.
10th September 2026

Modine to become Modexus Solutions

USA: Modine is to change its name to Modexus Solutions after completing the spinoff of its Performance Technologies business.
10th September 2026

ASHRAE and UNEP renew environmental agreement

USA: ASHRAE and the United Nations Environment Programme (UNEP) have renewed their longstanding memorandum of understanding to advance sustainable refrigeration and air conditioning.
10th September 2026

UK half-year heat pump installs down 22%

UK: The number of retrofit heat pump installations in domestic properties in the UK in the first half of this year were 22% down on the first six months of…