World News

Industry news and insights from Europe and around the World

UK News

Latest news and developments in the United Kingdom

Products

Keep up-to-date with the latest new products and technology

Features

General articles, applications and industry analysis

Turbomiser chiller provides a sound answer

UK: Bristol-based Cool-Therm has supplied a special ultra-low-sound, high efficiency 1.8MW air conditioning solution for a development of luxury apartments in Westminster, London.

The development, by Berkeley Group, includes a state-of-the-art gym, pool, sauna facilities and business suite. To meet high sustainability standards, the buildings are designed to achieve Level 4 of the Code for Sustainable Homes, the national UK standard for sustainable new homes.

Outstanding energy efficiency is achieved through the use of a CHP system, heat recovery ventilation, high levels of insulation and airtightness, and use of LED lighting.

High efficiency air conditioning is provided by two custom-designed Turbomiser chillers, selected for their low carbon cooling and exceptionally quiet operation in a special configuration.

The two buildings, Abell House and Cleland House, are located opposite one another on John Islip Street, in central London. The air conditioning plant is located in Cleland House, serving both buildings via pipework in a service tunnel under the main road.

The specification for the project is said to have required very low sound limits, due to its luxury residential nature. Air conditioning plant also had to be accommodated in restricted space, in order to maximise floor space for occupation.

Cool-Therm worked closely with M&E contractor Briggs and Forrester on a new design for the Turbomiser chillers to achieve the space and sound objectives. To reduce the chiller footprint, all associated plant is accommodated on a structural frame beneath the chiller, containing isolation valves, trace heating, sequence controls, cable tray, controls, BMS interface and connecting pipework.

According to Cool-Therm, the initial proposal was for a screw-based chiller solution with cooling towers. However, Briggs and Forrester worked with Berkeley to propose an alternative design using fully packaged Turbomiser chillers, which freed up space for additional residential capacity.

The sound specification for the project, by consultant AECOM, required a challenging limit of 51dBA at 10m. The original Turbomiser chillers in standard format were rated at 63dBA at 10m. Achieving the 12dBA reduction required re-engineering the conventional Turbomiser design.

Three additional sound attenuation measures were applied to the already low noise Turbocor-based chiller. The most substantial and visually striking is the addition of acoustic attenuation towers to both sides of each condenser fan, making an upper array of 16 towers per chiller.

Measuring 1.6m high and around 1m in diameter, each acoustic tower is lined with lead damping material and a perforated liner to absorb sound. Unusually, the condenser fan is positioned at the mid-point within the tower, providing attenuation at both air inlet and discharge sides.

A bull-nosed column in the tower further reduces turbulence, while the fans themselves are sickle-bladed low noise units, which help to streamline airflow and again reduce sound.

The Turbocor compressors are housed in acoustic enclosures, reducing sound from this source by some 6-7dBA. Finally, refrigerant discharge lines from compressors to condenser are lined with lead insulation, further reducing vibration and noise.

“The design takes a multi-element approach to both saving space and reducing sound. Our calculations were that it would achieve the required 51dBA at 10m, and this was confirmed in performance tests at Geoclima’s [the Italian equipment manufacturer] laboratory, with representatives of the contractor and consultant in attendance,” said Cool-Therm director Rob Young.

Following experience gained in the project, Cool-Therm says it is now developing an ultra-low noise version of the Turbomiser chiller. Equipped with a suite of sound attenuation technologies, it will offer what is claimed to be the lowest sound output for any commercially chiller on the market.

Latest News

15th April 2024

Invertek passes 3 million VFD landmark

UK: Welshpool-based Invertek Drives Ltd has celebrated producing its three millionth variable frequency drive.
15th April 2024

CDL opens Holmes Chapel branch

UK: Air conditioning distributor Cool Designs Ltd (CDL) has opened a new branch at Holmes Chapel near Crewe.
15th April 2024

Nidec to increase water cooling production

JAPAN: Nidec is to increase production of its coolant distribution unit (CDU) production line in Thailand from 200 to 2,000 units per month by June 2024.
15th April 2024

François Audo joins Enex as CEO

ITALY: François Audo has been appointed CEO of Enex Technologies, the Treviso-based manufacturer of cooling, heating, ventilation and refrigeration equipment.
15th April 2024

Cheap gas and policy changes hit heat pump sales

BELGIUM: Cheap gas and expensive bank loans are cited as two key reasons behind the dramatic fall in heat pump sales in Europe last year.
14th April 2024

IRAC 2024 returns to Dublin

IRELAND: IRAC 2024, Ireland’s biennial refrigeration and air conditioning exhibition, opens its doors next Friday with over 30 exhibitors showcasing their products and services.