BESA flags fire damper safety issue

UK: Inspections carried out by maintenance contractors have revealed that a “huge number” of fire and smoke dampers have been incorrectly installed in building ventilation systems.

The Building Engineering Services Association (BESA) has taken the unusual step in issuing an urgent warning after inspections found potential fire safety weakness in a large number of building ventilation systems.

It has issued an interim technical bulletin (VH001) ahead of a full update of its industry guidance for the Installation of Fire Dampers and Smoke Dampers (DW145) which is due for launch at the Association’s National Conference in October.

Head of technical Graeme Fox explained that many did not comply with manufacturers’ instructions and needed remedial action “without delay”.

“We have been alerted to the very dangerous practice of using self-drilling ‘tek’ screws which do not melt when temperatures rise during a building fire. This means spring-loaded dampers will not be released to contain the spread of fire within the zone and ensure the integrity of the fire stopping measure,” he said.

“Dampers must be secured by fusible fixings that allow the duct to break away otherwise the collapsing duct could pull the damper out of place and break the seal between the fire zones,” added Fox.

BESA’s technical committee sanctioned the technical bulletin, which is freely available on the Association’s website, to give contractors the information and appropriate terminology to alert clients to this potentially life-threatening problem.

The bulletin also updates the guidance and statutory requirements covering installation, testing and maintenance of fire dampers and smoke dampers including clients’ legal obligations to ensure their fire safety systems remain fit for purpose in line with the Regulatory Reform (Fire Safety) Order 2005 for England and Wales and the Fire Safety (Scotland) Regulations 2006.

It outlines the crucial role played by the penetration seal in ensuring the overall fire stopping integrity of an installation, the importance of maintenance teams being able to find and access dampers for testing and repair, and the need for designers and installers to seek expert advice from damper manufacturers.

“While this is clearly a very worrying situation, we can take some reassurance from the fact that this problem is being brought to our attention by the increasing frequency of fire damper inspections and tests as awareness grows of this extremely important issue,” said Fox.

“We would urge contractors to alert their clients immediately so all the necessary checks and repairs can be carried out.”

The document can reviewed and downloaded here.

Latest News

13th October 2026

Security firm warns on refrigeration asset security

USA: Following Sunday night’s cyberattack on French supermarkets, security company Claroty has warned food retailers that they should not assume that their refrigeration controllers are isolated and secure.
12th October 2026

Danfoss moves to mitigate cyberattack

FRANCE: Danfoss has said it is in close contact with supermarket customers in France affected by a cyberattack on Sunday night on its refrigeration controllers.
12th October 2026

Bitzer debuts screw compressor for data centre cooling

GERMANY: Bitzer is to launch a new screw compressor specifically developed for data centre cooling at the Chillventa exhibition, which begins tomorrow.
12th October 2026

Call for action on incorrect heat pump insulation

UK: Industry groups are backing calls for a crackdown on incorrectly specified and installed thermal insulation on heat pumps.
12th October 2026

French supermarkets hit by massive cyberattack

FRANCE: Cyberattackers are reported to have taken control of the refrigeration systems in hundreds of supermarkets in France, changing temperature settings and defrosting produce.
11th October 2026

Carrier cooler protects building workers

JAPAN: Construction workers building Tokyo’s Torch Tower, Japan’s tallest building, are being kept cool thanks to a temporary cooling system jointly developed by Carrier Japan.