World News

Industry news and insights from Europe and around the World

UK News

Latest news and developments in the United Kingdom

Products

Keep up-to-date with the latest new products and technology

Features

General articles, applications and industry analysis

Firm fined for breach of F-gas regulations

Environment-AgencyUK: In what has been described as an important result for the Environment Agency, a company has been prosecuted for breaching the F-gas regulations.

The prosecution for failing to recover a greenhouse gas was not, however, for releasing a refrigerant, but for the release of SF6, another highly potent greenhouse gas covered by the F-gas regulations. SF6 is used as an insulant in high voltage switchgear.

Schneider Electric Ltd, UK subsidiary of the French multinational automation, control and energy management company, was fined £3,000 for failing to recover the greenhouse gas that was released to atmosphere at Stanford-le-Hope, Essex in 2013. Basildon Magistrates’ Court also ordered the company to pay £18,368 costs.

While the Environment Agency has been widely criticised by the air conditioning and refrigeration industry for its failure to effectively police the F-gas regulations, the Agency’s investigating officer Claire Cox said: “This successful conviction demonstrates our commitment to ensuring compliance across all F-gas users and industries covered by these regulations.”

The case concerned the release of sulphur hexafluoride (SF6) gas from high voltage switchgear being installed at London Gateway Port. Following installation, busbars were found to be faulty and needed to be removed from within the circuit breaker. During that operation up to 15kg of SF6 was released.

With its GWP of 22,800, the release of 15kg SF6 is equal in CO2e terms to around 87kg of R404A.

During the case last Friday the Court was informed that Schneider Electric (SE) was sub-contracted by the principal contractor at the London Gateway Port project to install the switching gear. After installation, Schneider filled and pressurised the circuit breaker chambers with SF6 gas. Subsequently they discovered that the busbars were faulty and needed to be removed for modification.

Schneider used its subcontractor, Metricab Power Engineering Ltd, to remove the busbars. Metricab was not informed, and did not realise, that the switchgear had been filled with SF6. Consequently when the work was done on 10 June 2013 the SF6 gas was not recovered using F-gas qualified engineers (as required by the law) and was released to the earth’s atmosphere.

Schneider Electric reported the release to the Environment Agency and Health and Safety Executive.

It was said that Schneider Electric Ltd did not generate any documents such as method statements or risk assessments in relation to SF6. Nor did it review the method statement and risk assessment prepared by Metricab which made no mention of SF6 for the removal of the busbars.

The gas was released for 1-2 hours before an employee of Schneider Electric realised what was happening and raised the alarm.

Latest News

17th July 2026

Daikin NEXIO Max rooftop heat pump on R32

USA: Daikin Comfort Technologies North America has launched the Daikin NEXIO Max packaged heat pump, an inverter-driven rooftop unit using R32 refrigerant.
17th July 2026

MHI ships 10MW chiller for data centre tests

JAPAN: Mitsubishi Heavy Industries (MHI) has shipped its 10MW  centrifugal chiller test unit to the US in support of moves to address the power and cooling challenges of AI data…
17th July 2026

Beijer Ref reports record quarter

SWEDEN: Wholesaler Beijer Ref has reported record-high sales and profit in the second quarter of 2026.
16th July 2026

Parts Town offers F-gas Category 1 training

UK: Spare parts distributor Parts Town UK is to offer F-gas Category 1 (FCAT1/Course 2079-11) courses at its training facility in Cannock.
16th July 2026

Bringing STEM to life for Birmingham pupils

UK: Daikin has welcomed pupils and teachers to its Birmingham Training Academy, giving the children a chance to explore science and engineering outside the classroom.
15th July 2026

Testing AC in real world conditions

JAPAN: The General Group is to build a demonstration house to test air conditioning systems for high-performance homes, shifting from individual rooms to whole house air conditioning.