USA: Chemours has claimed that in analysis tests on five commercially available refrigerants on the US market, four failed to meet AHRI 700 specifications.

Over a 9-month period, Chemours claims it purchased five commercially available 25lb (11.3kg) cylinders of R410A from competing brands. The cylinders were then sampled and analysed under AHRI 700 testing conditions. Chemours claims that four out of five of the cylinders, labelled as “meeting industry standards,” in fact failed to meet the AHRI 700 specifications for blend composition, moisture, and non-condensables. 

AHRI 700 specifies acceptable levels of contaminants for fluorocarbon, hydrocarbon, and carbon dioxide refrigerants regardless of source and lists acceptable test methods. 

Although R410A is generally described as a 50/50 blend of R125 and “mildly flammable” R32, the AHRI 700 standard allows for 49.5%-51.5% of R125 and 48.5%-50.5% of R32. Two of the unnamed refrigerants tested by Chemours are said to have exceeded these specifications. The worst example comprised just 43.58% R32.

Results from the Chemours tests

Two other refrigerants exhibited contaminant levels above the accepted AHRI 700 limits. One, in particular, is said to have exceeded the specifications for both moisture and non-condensables. Chemours’ analysis is said to have revealed 3.06% by volume of non-condensables, more than twice the limit of less than 1.5%, and 11.7ppm of moisture, against the specification of less than 10ppm.

In a related investigation, Chemours says that several cylinders of competitor R404A and R407C refrigerants were also shown to contain what it describes as “low-quality” mixtures.

Chemours warns that bad compositions, non-condensables, and high moisture may lead to flammability risks, increased discharge temperature, damage to the compressor and metering device, poor cooling capacity and decreased system energy efficiency.

Latest News

26th July 2024

Panasonic partners with Plug Me In

UK: Panasonic has announced a collaboration with Scottish Power’s Manchester-based heat pump installers Plug Me In to provide Panasonic Aquarea heat pumps as part of Scottish Power’s offering.
26th July 2024

Seeking a solution to data centre cooling demand

USA: The University of Missouri is developing a new type of cooling system which it claims could dramatically reduce energy demands on data centres.
25th July 2024

Carrier sales up 12%

USA: Carrier has reported strong Q2 2024 financial results with sales up 12% to $6.7bn compared to last year.
25th July 2024

Prefabricated hydronic balancing and control

DENMARK: The latest solution from Danfoss is a prefabricated hydronic balancing and control solution for four-pipe heating and cooling change-over systems.
25th July 2024

BUS applications down 10% in June

UK: The 2,687 applications to the UK government’s Boiler Upgrade Scheme (BUS) last month were down 10% on May.
24th July 2024

MHI Projects team ensures smooth delivery

UK: Dedicated support from the MHI Projects team has helped provide a climate control upgrade for the UK home of a leading global glass processing specialist.